METOX SOLAR CLEAN Solar Panel Cleaning Solution
Key Features
- Increases energy efficiency
- Leaves no limescale spots
- Antistatic property (delays dust adhesion)
- Biodegradable
- Concentrated formula
Product Details and Variants
METOX SOLAR CLEAN is a concentrated solar panel cleaning fluid that cleans the panel surface at solar power plants without damaging it. It does not damage the anti-reflective coating on the panel glass or the aluminium frame.
Dust, bird droppings, pollen and industrial pollution that build up on the panel surface can reduce energy efficiency significantly. METOX SOLAR CLEAN removes dust, dirt and mineral deposits without damaging the panel and restores output.
Key features:
- Increases energy efficiency
- Leaves no limescale spots
- Antistatic property — delays dust adhesion
- Biodegradable
- Concentrated formula
Why does a dirty panel lose output?
A photovoltaic cell converts the light falling on it into electricity. Every obstacle on the surface breaks the first link in this chain.
Dust, pollen, bird droppings and industrial pollution that build up on the panel surface over time prevent the cells from receiving sunlight efficiently. This creates a "shading effect" and leads to losses in energy production.
The size of the loss depends on the type of soiling:
| Soiling | Source | Effect |
|---|---|---|
| Uniform dust layer | Wind, arid climate, farmland | Even light loss across the whole surface; output falls proportionally |
| Bird droppings | Sites near settlements and farmland | Complete local shading — the most harmful type |
| Pollen and organic film | Seasonal, vegetation | Sticky layer; does not come off with dry cleaning |
| Industrial pollution | Factories, construction sites, road dust | Greasy, dusty mixture; water alone is not enough |
| Limescale spots | Incorrect cleaning with hard water | Permanent mineral layer; builds up with every wash |
Why does local shading cause disproportionate damage? The cells in a panel are connected in series. When a single cell is shaded, it limits the current in that string — the output lost is much greater than the percentage of the area shaded. The shaded cell also heats up (hot spot) and can suffer permanent damage over time. This is why bird droppings are a more urgent problem than a wide layer of dust.
Why isn't water alone enough?
The most common practice among site teams is to wash panels with pressurised water. This has two problems:
1. Organic and greasy soiling does not come off. Pollen, bird droppings and greasy industrial dust get wet but do not dissolve. They stay on the surface, leaving a thin film.
2. Hard water leaves limescale spots. The calcium and magnesium in mains or well water leave mineral spots when they dry on the panel surface. These spots build up with every wash and, over time, block more light than before the panel was cleaned. This is the paradox often seen on site: the more a panel is washed, the less it produces.
METOX SOLAR CLEAN solves both problems: it dissolves organic dirt and prevents limescale formation.
Product advantages
Surface-friendly. Does not damage the delicate anti-reflective coating on the panel glass, the silicone seals or the aluminium frame.
No limescale spots. Prevents mineral deposits even when working with hard water; no spots form as the surface dries.
Antistatic. The antistatic effect left on the surface after cleaning delays dust from adhering again — cleaning intervals become longer.
Concentrated. Used diluted with water at 1/3 – 1/5. On large sites, the amount of water transported and the storage space required are reduced.
Environmentally compatible. Biodegradable. Because solar power plant sites are mostly located on farmland or in natural areas, this is also important from a regulatory point of view.
Why do you need to take care of the anti-reflective coating?
Modern panel glass carries a thin anti-reflective (AR) coating that reduces reflection and increases light transmission. This coating contributes directly to the panel's efficiency and is sensitive to abrasive or strongly alkaline cleaners.
This is what happens when the wrong product is used: the coating is abraded at micro level, the surface starts to look dull and the panel produces less permanently. This damage is irreversible and also puts the panel warranty at risk.
For this reason, when cleaning solar power plants:
- Do not use abrasive powders or scouring pads
- Do not use strongly alkaline general-purpose cleaners
- Do not use household products such as glass cleaner / washing-up liquid
- Use only products approved for panels
Application
When should panels be cleaned?
- Early in the morning or in the late afternoon. Work while the panel surface is cool. At midday the panel reaches 60–70 °C; water poured on it evaporates instantly and leaves spots, and the sudden cooling creates a risk of thermal shock on the glass.
- Working in cloudy weather is also suitable.
- Avoid windy weather — the solution is blown away and the application is not uniform.
How is it applied?
- First remove coarse dust and loose dirt such as leaves from the surface dry.
- Dilute METOX SOLAR CLEAN with water at 1/3 – 1/5 (the heavier the soiling, the closer the ratio to 1/3).
- Apply to the surface with a soft brush, sponge or panel cleaning robot.
- Leave for a short time so that the soiling dissolves.
- Rinse with plenty of water.
- If necessary, remove excess water with a soft squeegee.
Do not use: abrasive pads, metal-bristle brushes, high-pressure jets (risk of damage to seals and frames) or household detergents.
How often? The site's location decides. Cleaning frequency increases at sites near farmland, construction sites or in dusty regions, and decreases in regions with regular rainfall. The practical criterion is not the calendar but production data: if output is falling under the same irradiance conditions, it is time to clean.
The return on cleaning
Panel cleaning is not a maintenance expense but a direct production item. The calculation is simple:
- Take the site's annual production (kWh).
- Determine the loss rate caused by soiling — this rate varies from site to site according to location, type of soiling and cleaning frequency.
- Calculate the monetary value of the lost energy.
- Compare this amount with the cost of cleaning (chemicals + labour + water).
At sites with high dust levels, the cost of cleaning is small compared with the output gained. Regular cleaning shortens the payback period of the investment.
Areas of use
- Utility-scale solar power plants
- Rooftop commercial and industrial PV systems
- Agricultural irrigation and agrivoltaic applications
- Residential rooftop systems
- Solar collectors and thermal panel surfaces
- Maintenance companies providing panel cleaning services
Quick Action
Request a quote now to get detailed information, request technical specifications or place an order for this product.
Product Details and Variants
Product Category
You can request MSDS and TDS documents from our technical documents page.
METOX SOLAR CLEAN — Frequently Asked Questions
Dust, pollen, bird droppings and industrial pollution on the surface block the light reaching the panel and cause a loss of output. The size of the loss varies according to the site's location, the type of soiling and the time since the last cleaning. To see the real rate, compare your production data under the same irradiance conditions.
No. Water does not dissolve organic and greasy soiling such as pollen and bird droppings. In addition, hard water leaves limescale spots on the surface, which build up with every wash and reduce light transmission even further.
No. METOX SOLAR CLEAN is formulated so as not to damage the anti-reflective coating, silicone seals or aluminium frame.
Do not use them. Household cleaners can abrade the anti-reflective coating. This damage is irreversible, makes the panel permanently less efficient and puts the warranty at risk.
Early in the morning or in the late afternoon, while the panel surface is cool. At midday the panel gets very hot; water poured on it evaporates instantly and leaves spots, and there is a risk of thermal shock.
Decide by production data, not by the calendar: if output starts to fall under the same irradiance conditions, it is time to clean. Frequency increases at sites in dusty and agricultural regions.
Not recommended. High pressure can damage panel seals and frame joints. Use a soft brush, sponge or panel cleaning robot instead.
The antistatic effect left on the surface after cleaning delays dust from adhering again. This extends the time between two cleanings and lowers maintenance costs.
It is a concentrate; it is used diluted with water at 1/3 – 1/5. The heavier the soiling, the closer the ratio to 1/3. On large sites it reduces the amount of water transported and the storage space required.
The product is biodegradable. Even so, it is recommended that rinse water is managed in line with the site's drainage arrangements.
We provide product supply and application consultancy. Tell us your site size and type of soiling — we will calculate the suitable dilution ratio and consumption. Contact: +90 212 222 37 52 · satis@akemkimya.com.tr